Kasa Smart Thermostatic Radiator Valve KE100 Display Shows E1/E2 Error code

Tapo Others
Updated 12-13-2023 03:52:46 AM 12336
This Article Applies to: 

If the display of Kasa thermostatic shows error codes E1 or E2, you may try the following troubleshooting.

The display shows E1

1. Rotate the valve, and then the valve will calibrate automatically.

2. Check if the valve is installed properly.

3. Check if the connector is M30 x 1.5. If not, choose a proper adapter

The display shows E2

1. The valve might be blocked by calcification. Use a spanner or a similar tool to move the pin in and out to unblock the valve.

2. Re-install the old valve head and open/close it multiple times to improve the pin’s movement. Then, restart and remount the new valve.

3. Replace the batteries.

If the troubleshooting steps above didn’t fix the issue, please contact support for further assistance.