S6500-24G4XF
НовOmada Pro 24-Port Gigabit Stackable L3 Managed Switch with 4 10G Slots
- 24× Gigabit RJ45 ports and 4× 10 Gbps SFP+ slots
- Physical stacking for built-in redundancy and performance
- L3 Features: OSPF, BGP, IS-IS, VRRP, PIM-SM/PIM-DM/PIM-SSM, ECMP, PBR
- Security Strategies: MACsec, Secure Boot, RADSEC, IMPB, SFTP, 802.1X
- Highly Available with two internal fixed power supplies, VRRP, ERPS, and BFD
- Easy O&M: NETCONF, Configuration Rollback, Hot Patching, and RSPAN
- Centralized cloud management via the web or the Omada app†
What This Product Does
Omada Pro S6500-24G4XF is a high-performance L3 managed switch tailored for the access layer, featuring L3 routing, fast 10 Gbps wired speeds, stacking options, and redundant power supply modules. It includes 24× Gigabit RJ45 ports, 4× 10 Gbps SFP+ slots, physical stacking ability, and centralized management. Integrated with strong security, easy O&A, and extensive management features, S6500-24G4XF offers a dependable networking solution for SMBs, enterprises, and ISPs.
High-speed Connectivity and Powerful Stacking
24× Gigabit RJ45 ports and 4× 10 Gbps SFP+ slots provide up to 128 Gbps switching capacity per unit. Physical stacking of up to 12 units△ enhances network performance and redundancy.
Abundant Layer 3 Capabilities
Comes with abundant Layer 3 routing protocols that support a scalable network, such as OSPF, BGP, IS-IS, VRRP, PIM-SM/PIM-DM/PIM-SSM, ECMP, and PBR. In complex large-scale network environments, dynamic routing protocols automatically adapt to changes in network topology and select the best transmission path based on real-time network conditions to maintain stability.
Comprehensive Security Functions
Defend against a range of network threats with MACsec, Secure Boot, RADSEC, IMPB, SFTP, and 802.1X. MACsec works with the 802.1X protocol to ensure secure communication of all traffic on Ethernet links. Secure Boot protects the operating system from malicious attacks.
Highly Available
Internally fixed redundant power supplies and VRRP make it an ideal choice for reliable networking architecture. ERPS supports rapid protection and recovery in a ring topology, while BFD enables sub-second failure detection for rapid routing protocol rebalancing.
Easy Operation and Maintenance
The switch can be configured and managed based on the NETCONF protocol, reducing manual configuration errors and improving software upgrade efficiency. Configuration Rollback restores previous settings if errors occur. Hot patching technology allows software defects to be fixed without device restart, preventing business interruptions.
Omada Pro Integration
Integration into the Omada Pro system brings centralized cloud management and a series of management features, such as Zero-Touch Provisioning (ZTP) and Intelligent Anomaly Detection.† Omada Pro’s Software Defined Networking (SDN) platform integrates network devices, including access points, switches, and routers, providing 100% centralized cloud management. Omada Pro creates a highly scalable network—all controlled from a single interface.
Apart from central management via the web or Omada app, S6500-24G4XF can be managed through an intuitive web GUI or industry-standard CLI, both secured with SSL or SSH encryption. SNMP (v1/v2c/v3) and RMON support provide status polling and abnormal event notifications.
ХАРДУЕРНИ ХАРАКТЕРИСТИКИ | |
---|---|
Интерфейс | • 24× 10/100/1000 Mbps RJ45 Ports• 4× 1/10Gbps SFP+ Slots*• 2× USB 2.0 Ports• 1× RJ45 Console Port• 1× USB Type-C Console Port• 1× RJ45 Management Port |
Брой вентилатори | Four Internal Fixed Fans |
Захранване | Two Internal Fixed Power Supply Modules (100–240 VAC, 50/60 Hz) |
Размери (Ш x Д x В ) | 17.3 × 15.0 × 1.7 in (440 × 380 × 44 mm) |
Монтаж | Rackmountable |
Макс. консумация на енергия | 28.4 W (220 V/50 Hz) |
Max Heat Dissipation | 96.91 BTU/hr (220 V/50 Hz) |
ПРОИЗВОДИТЕЛНОСТ | |
---|---|
Комутационен капацитет | 128 Gbps per Unit |
Stacking | • Stacking Number: 12 (standalone mode)• Stacking Port: 10G SFP+ Slot (all uplink ports can be used as stacking ports)**• Stack Bandwidth: Up to 80 Gbps (4 stacking ports) |
Скорост на предаване на пакети данни | 95.2 Mpps |
Таблица на МАС адресите | 32 K |
Packet Buffer Memory | 3 MB |
Jumbo кадър | 9 KB |
СОФТУЕРНИ ХАРАКТЕРИСТИКИ | |
---|---|
Качество на услугата | • Class of Service- 8 Queues of Priority- Port Priority- IEEE 802.1p Priority- DSCP Priority- Queue Min-Bandwidth- Schedule Mode (SP, WRR, SP+WRR)• Bandwidth Control- Rate Limit- Storm Control• Voice VLAN• User-Defined OUI• Smoother Performance• Action for Flows- QoS remark (802.1P Remark, DSCP Remark)• WRED profile: 16 |
L3 Features | • L3 Interface: 256 (IPv4,IPv6)• Static Route: 1,024 IPv4, 512 IPv6• Host Route Table: Max 6,100 entries• IPv4 Network Router entries: 10,240 (shared with IPv6 Network Router entries)• IPv6 Network Router entries: 5,120 (shared with IPv4 Network Router entries)• ECMP: 256 entries, max 32 ECMP Nexthops per Destination• Static ARP: 512 static entries• Dynamic ARP: 7,680 dynamic entries• ND: 7680• DHCP Server: Max 64 IP pool, Max 8,000 IP entries• DHCPv4/v6 Relay• VRRP: Version v2/v3, Max 64 instances, Max 32 Virtual IP per instance• OSPFv2- OSPF Instance: 16- Network Entries: 256 entries- Area Entries for Stub or NSSA: 16 per instance- Area Range Entries: 16 per instance- Virtual-link Entries: 16 per instance• OSPFv3- Area Entries for Stub or NSSA: 16 per instance- Area Range Entries: 16 per instance• RIPv1/v2- Network Entries: 256- Redistribute Entries: 20• RIPng• IS-IS- IS-IS Interfaces: 128- IS-IS Area Numbers: 3- Max Redistribute Configs: 10- IS-IS IPV6- IS-IS BFD• BGP: Max 20 redistribute configs• PIM-DM/PIM-SM/PIM-SSM- IP Multicast Route Entries: 1K- PIM Neighbors: 256- Max PIM Interfaces: 128• IGMP: Version v1/v2/v3, Max 2,048 multicast groups• BFD: 16 template numbers, 8 session numbers• PBR• uRPF |
L2 and L2+ Features | • Link Aggregation• Spanning Tree Protocol• Port-based and VLAN-based Loopback Detection• 802.3x Flow Control• ERPS• Mirroring• RSPAN• MAC Address Table• Multicast- IGMP Snooping- MLD Snooping- Multicast VLAN Registration (MVR)- Max Multicast Table: 4K (IPv4, IPv6)- Fast Leave- Static Multicast Groups- Multicast Filtering- IGMP Snooping Authentication |
Разширени характеристики | • Automatic Device Discovery†• Batch Configuration†• Batch Firmware Upgrading†• Intelligent Network Monitoring†• Abnormal Event Warnings†• Unified Configuration†• Reboot Schedule†ISP Features:• 802.3ah Ethernet Link OAM • L2PT (Layer 2 Protocol Tunneling) • Device Link Detect Protocol (DLDP)• DDM• sFlow |
VLAN | • Max 4K VLAN Group (802.1q VLAN)• 802.1Q Tagged VLAN• MAC VLAN Entries: 200• Multicast VLAN• Management VLAN• VLAN VPN (QinQ): Max 256 entries• GVRP• Protocol VLAN: Protocol Template 16, Protocol VLAN 12 entries• Voice VLAN• Private VLAN |
Защита | • Port Isolation• CPU-Defend• ARP Inspection (Dynamic ARP Inspection)• DoS Defend• IP-MAC-Port Binding-1,024 Entries- DHCP Snooping- ARP Inspection- IPv4 Source Guard• IPv6-MAC-Port Binding-1,024 Entries- DHCPv6 Snooping- ND Detection- ND Snooping- IPv6 Source Guard• DHCP Filter• Static/Dynamic Port Security- Up to 64 MAC addresses per port• Broadcast/Multicast/Unknown-unicast Storm Control- kbps/ratio control mode• 802.1X- Port base authentication- Mac base authentication- VLAN Assignment- MAB- Guest VLAN- RADIUS authentication and accountability support• AAA (including TACACS+)• Secure web management through HTTPS with SSLv3/TLS 1.2• Secure Command Line Interface (CLI) management with SSHv2• IP/Port/MAC-based access control• MACSec (-128, -256)• Secure boot• RADSEC |
Virtualization | • IP Tunnel- IPv6 over IPv4- IPv6 over IPv4 GRE- IPv4 over IPv4 GRE- Tunnel entries: 100 |
MANAGEMENT | |
---|---|
Omada App | Yes, through Omada Pro Controller |
Centralized Management | • Omada Pro Cloud-Based Controller• Omada Pro Hardware Controller• Omada Pro Software Controller |
Cloud Access | Yes, through Omada Pro Controller |
Zero-Touch Provisioning | Yes. Requiring the use of Omada Pro Cloud-Based Controller. |
Management Features | • Web-based GUI• Command Line Interface (CLI) through console port, telnet• SNMPv1/v2c/v3- Trap/Inform- RMON (1, 2, 3, 9 groups)• SDM Template• DHCP/BOOTP Client• 802.1ab LLDP/LLDP-MED• DHCP Auto Install• Dual Image, Dual Configuration• CPU Monitoring• Cable Diagnostics• Password Recovery• SNTP• System Log• IEEE 802.3az Energy Efficient Ethernet (EEE)• Configuration Rollback• Hot Patching• NETCONF |
ДРУГИ | |
---|---|
Съдържание на пакета | • S6500-24G4XF Switch• 2× Power Cords• RJ45 Console Cable• Quick Installation Guide• Rackmount Kit• Rubber Feet |
Системни изисквания | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux. |
Околна среда | • Operating Temperature:-5 °C to 50 °C (23 °F to 122 °F) @ 300 meters-5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters-5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters• Storage Temperature: -40 °C to 70 ℃ (-40 ℉ to 158 ℉)• Operating Humidity: 10–90% RH non-condensing• Storage Humidity: 5–90% RH non-condensing |
†These functions require the use of the Omada Pro SDN Controller. Zero-Touch Provisioning requires the use of the Omada Pro Cloud-Based Controller.
△Supports 12 units of physical stacking in standalone mode.
*No more than two 10G RJ45 SFP+ modules are supported, and they can only be inserted into SFP+ slots 25&27.
**To ensure performance and stability, the slots need to work at 10 Gbps when used as stacking ports.