Objective

This article describes how to configure Quality of Service on Omada gateway via Omada Controller.

Requirements

  • Omada Gateway series
  • Omada Software Controller / Hardware Controller / Cloud-Based Controller

Introduction

Omada Gateways supports Quality of Service (QoS) to identify, classify, and mark incoming traffic. With the QoS feature, you can intelligently allocate and utilize network bandwidth based on the network's status and traffic information.

Network Requirements: A home network user uses IPv4 to access the internet, with a total bandwidth of 1000Mbps. The requirement is to divide the home network into three categories: Host, IoT, and Guest, and achieve the following network bandwidth allocation:

  • Limit the internet bandwidth for the Guest network to 20 Mbps and restrict the IoT network's internet bandwidth to 10 Mbps to ensure the Host network performance.
  • Set a maximum bandwidth limit of 20 Mbps for FTP (or any other protocol) traffic to prevent excessive bandwidth consumption by large FTP downloads, which could impact other applications.
  • Ensure high priority for VoIP service traffic.

Other traffic that doesn't fall into the above categories will not be subject to bandwidth restrictions.

In this example, you can configure Quality of Service as follows.

Configuration

Step 1. Log in to the Controller via web browser, go to Site Settings > Profiles > Groups to configure specific IPv4 group to identify IoT network and Guest network, as shown in the figure below. Here, you can also configure the IPv6 group for IPv6 services.

The position to create a new IP Group on Controller.

Step 2. Go to Transmission > Quality of Service > Bandwidth Control to allocate bandwidth resources to different categories of traffic on the WAN based on actual usage. Four classes are available: Class 1, Class 2, Class 3, and Others.

  • Set Inbound/Outbound Bandwidth as 1000000.
  • Specify Guest network traffic as Class 1 and limit the bandwidth to 20Mbps: As shown in the figure below, set the Class 1 upstream to 1000 Mbps x 2% = 20 Mbps and the downstream to 1000 Mbps x 2% = 20 Mbps.
  • Specify IoT traffic as Class 2 and set it to 10 Mbps, 1% of the total bandwidth.
  • Specify FTP traffic as Class 3 and set it to 20 Mbps, 2% of the total bandwidth.
  • Others cannot be configured. The remaining bandwidth after allocating for Class 1, Class 2, and Class 3 is 95%.

The configurations of bandwidth control, including WAN Interface/Status, and so on.

Step 3. Go to Site Settings > Transmission > Quality of Service >Class Rule to configure Class Rules. Configure the parameters for the Guest_network_v4 as shown in the figure below.

The configurations of class rule, including Status/IP Version and so on.

  • IP Version: This identifies IPv4 traffic and IPv6 traffic.
  • Local Address: This identifies the source address of the traffic. Select the IP Group configured in Step 1 to differentiate the network.
  • Remote Address: This identifies the traffic destination address. If there are no specific requirements to restrict access to specific websites, it is generally set to IPGROUP_ANY.
  • DSCP: This identifies the DSCP field of the traffic (located in the IP header) used to classify the traffic's quality of service.
  • Service Name: This identifies the traffic type based on the source and destination ports of the packets.
  • QoS Class: Select from the classes set in Step 2 to apply different bandwidth limits to the traffic.

The configuration of the IoT_Network_v4 and FTP traffic is similar to the Guest network.

The class rule list you configured.

Note: The Service Type has 13 rules by default, as shown in the figure below.

If the default rules cannot meet your need, click Add to configure a new Gateway QoS Service.

The Service Type has 13 rules by default, here you can choose what type you need.

Step 4. Go to Site Settings > Transmission > Quality of Service >VoIP Prioritization to enable the first priority for VoIP traffic as shown in the figure below. With this feature enabled, the Omada Gateway prioritizes SIP/RTP packets with the specified destination port (typically port 5060) in congested network environments.

Enable the first priority for VoIP traffic on Controller.

Verification

Go to Insight > QoS Data to view the WAN’s real-time traffic statistics of each class, as shown in the figure below. With the real-time traffic statistics, you can determine if the traffic classification and bandwidth control are working.

Check the QoS data to determine if the traffic classification and bandwidth control are working.

Conclusion

You have now successfully configured Quality of Service on the Omada Gateway.