JetStream 10-Port Gigabit Smart Switch with 8-Port PoE+
- 61 W PoE Budget: 8× 802.3af/at-compliant PoE+ ports with a total power supply of 61 W*.
- Full Gigabit Ports: 8× gigabit PoE+ ports and 2× gigabit SFP Slots provide high-speed connections.
- Integrated into Omada SDN: Zero-Touch Provisioning (ZTP)**, Centralized Cloud Management, and Intelligent Monitoring.
- Centralized Management: Cloud access and Omada app for ultra convenience and easy management.
- Robust Security Strategies: IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm Control, DHCP Snooping, 802.1X, Radius Authentication, and more.
- Optimized Voice and Video Applications: L2/L3/L4 QoS and IGMP snooping.
- Versatile Management: WEB/CLI managed modes, SNMP, and RMON bring abundant management features.
Learn more about TP-Link PoE technology >
Centralized Management
Professional 10-Port Gigabit Smart
Switch with 8-Port PoE+
Easy to Use, Multi-Purpose PoE Switch with Powerful Performance
TL-SG2210P
-
Centralized
Cloud ManagementOmada SDN Platform Integration
-
Advanced
L2+ FeaturesStatic Routing, ACL,
IGMP Snooping and More -
Abundant
Security StrategiesLAN Area
Investment Protection -
PoE+ Output
8 PoE+ Ports with Total
61 W Power Budget*
Software Defined Networking (SDN) with Cloud Access
Omada’s Software Defined Networking (SDN) platform integrates network devices, including access points, switches and gateways, providing 100% centralized cloud management. Omada creates a highly scalable network—all controlled from a single interface. Seamless wireless and wired connections are provided, ideal for use in hospitality, education, retail, offices, and more.
Mount Wall
Plate Outdoor Unified Management Interface Controllers Cloud Access Cloud
Related Cases
-
Soborka ISP
TP-Link Helps ISP Soborka Provide Better Service for Subscribers
Soborka ISP
TP-Link Helps ISP Soborka Provide Better Service for Subscribers
“TP-Link’s products offer tremendous value, which allowed us to reduce the cost of updating our large network without compromising performance. Our customers are much more satisfied with the network since the upgrade. It has done a lot to improve our reputation.” —Soborka's CEO
HARDWARE FEATURES | |
---|---|
Standards and Protocols | IEEE 802.3i, IEEE 802.3u, IEEE 802.3z, IEEE 802.3ab,IEEE 802.3ad, IEEE 802.3af, IEEE 802.3at, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s,IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.1x |
Interface | • 8× 10/100/1000Mbps RJ45 Ports (Auto-Negotiation/Auto MDI/MDIX)• 2× 1000Mbps SFP Slots |
Network Media | • 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m)• 100BASE-TX/1000Base-T: UTP category 5, 5e or above cable (maximum 100m)• 1000BASE-X: MMF, SMF |
Fan Quantity | Fanless |
Power Supply | • 100~240VAC, 50/60Hz• External Power Adapter(Output: 53.5VDC/1.31A) |
PoE Ports (RJ45) | • Standard: 802.3af/at compliant• PoE Ports: 8 Ports• Power Supply: 61 W* |
Dimensions ( W x D x H ) | 8.2 x 4.9 x 1.0 in (209 x 126 x 26mm) |
Mounting | Desktop / Wall-Mounting |
Max Power Consumption | • V3.2: 76.5 W (220 V/50 Hz) (with 61 W PD connected); 10.3 W (220 V/50 Hz) (no PD connected)• V4: 74.4 W (220 V/50 Hz) (with 61 W PD connected)• V5: 77.8 W (110 V/60 Hz) (with 61 W PD connected) |
Max Heat Dissipation | • V3.2: 261.02 BTU/hr (220 V/50 Hz) (with 61 W PD connected); 35.14 BTU/hr (220 V/50 Hz) (no PD connected)• V4: 253.89 BTU/hr (220 V/50 Hz) (with 61 W PD connected)• V5: 265.3 BTU/hr (110 V/60 Hz) (with 61 W PD connected) |
PERFORMANCE | |
---|---|
Switching Capacity | 20 Gbps |
Packet Forwarding Rate | 14.88 Mpps |
MAC Address Table | 8K |
Packet Buffer Memory | 4.1 Mbit |
Jumbo Frame | 9 KB |
SOFTWARE FEATURES | |
---|---|
Quality of Service | • 802.1p CoS/DSCP priority• 8 priority queues• Priority Schedule Mode- SP (Strict Priority)- WRR (Weighted Round Robin)• Queue Weight Config• Bandwidth Control- Port/Flow based Rating Limit• Smoother Performance• Storm Control- Multiple Control Modes(kbps/ratio)- Broadcast/Multicast/Unknown-Unicast Control |
L2 and L2+ Features | • 16 IP Interfaces- Support IPv4/IPv6 Interface• Static Routing- 32 IPv4/IPv6 Static Routes• DHCP Server• DHCP Relay- DHCP Interface Relay- DHCP VLAN Relay• DHCP L2 Relay• Static ARP• Proxy ARP• Gratuitous ARP• Link Aggregation- Static link aggregation- 802.3ad LACP- Up to 8 aggregation groups and up to 8 portsper group• Spanning Tree Protocol- 802.1D STP- 802.1w RSTP- 802.1s MSTP- STP Security: TC Protect, BPDU Filter/Protect,Root Protect• Loopback Detection• Flow Control- 802.3x Flow Control• Mirroring- Port Mirroring- CPU Mirroring- One-to-One- Many-to-One- Flow-Based- Ingress/Egress/Both• Device Link Detect Protocol (DLDP)• 802.1ab LLDP/ LLDP-MED |
Advanced Features | • Automatic Device Discovery• Batch Configuration• Batch Firmware Upgrading• Intelligent Network Monitoring• Abnormal Event Warnings• Unified Configuration• Reboot Schedule |
VLAN | • VLAN Group- Max. 4K VLAN Groups• 802.1Q tag VLAN• MAC VLAN: 12 Entries• Protocol VLAN• GVRP• Voice VLAN |
Access Control List | • Support up to 230 entries• Time-Range- Time Slice- Week Time-Range- Absolute Time-Range- Holiday• Time-based ACL• MAC ACL- Source MAC- Destination MAC- VLAN ID- User Priority- Ether Type• IP ACL- Source IP- Destination IP- IP Protocol- TCP Flag- TCP/UDP Source Port- TCP/UDP Destination Port- DSCP/IP TOS• IPv6 ACL• Combined ACL• Rule Operation- Permit/Deny• Policy Action- Mirror- Rate Limit- Redirect- QoS Remark• ACL Rules Binding- Port Binding- VLAN Binding• Actions for flows- Mirror (to supported interface)- Redirect (to supported interface)- Rate Limit- QoS Remark |
Security | • AAA• 802.1X- Port based authentication- MAC (Host) based authentication- Authentication Method includes PAP/EAP-MD5- MAB- Guest VLAN- Support Radius authentication andaccountability• IP/IPv6-MAC Binding- 512 Binding Entries- DHCP Snooping- DHCPv6 Snooping- ARP Inspection- ND Detection• IP Source Guard- 253 Entries- Source IP+Source MAC• IPv6 Source Guard- 183 Entries- Source IPv6 Address+Source MAC• DoS Defend• Static/Dynamic/Permanent Port Security- Up to 64 MAC addresses per port• Broadcast/Multicast/Unicast Storm Control- kbps/ratio control mode• Port Isolation• Secure web management through HTTPS withSSLv3/TLS 1.2• Secure Command Line Interface (CLI)management with SSHv1/SSHv2• IP/Port/MAC based access control |
IPv6 | • IPv6 Static Routing and ACL• IPv6 Dual IPv4/IPv6• IPv6 Interface• Multicast Listener Discovery (MLD) Snooping• IPv6 neighbor discovery (ND)• Path maximum transmission unit (MTU) discovery• Internet Control Message Protocol (ICMP)version 6• TCPv6/UDPv6• IPv6 applications- DHCPv6 Client- Ping6- Tracert6- Telnet(v6)- IPv6 SNMP- IPv6 SSH- IPv6 SSL- Http/Https- IPv6 TFTP |
MIBs | • MIB II (RFC1213)• Bridge MIB (RFC1493)• P/Q-Bridge MIB (RFC2674)• Radius Accounting Client MIB (RFC2620)• Radius Authentication Client MIB (RFC2618)• Remote Ping, Traceroute MIB (RFC2925)• Support TP-Link private MIBs• RMON MIB(RFC1757, rmon 1,2,3,9) |
MANAGEMENT | |
---|---|
Omada App | Yes, through• Omada Cloud-Based Controller (Not Supported by TL-SG2210P v4)• OC300• OC200• Omada Software Controller |
Centralized Management | • Omada Cloud-Based Controller (Not Supported by TL-SG2210P v4)• Omada Hardware Controller OC300• Omada Hardware Controller OC200• Omada Software Controller |
Cloud Access | Yes, through• Omada Cloud-Based Controller (Not Supported by TL-SG2210P v4)• OC300• OC200• Omada Software Controller |
Zero-Touch Provisioning | Yes. Requiring the use of Omada Cloud-Based Controller (Supported by TL-SG2210P v3.2, v5 and above, while is not supported by TL-SG2210P v4) |
Management Features | • Web-based GUI• Command Line Interface (CLI) through telnet• SNMPv1/v2c/v3• SNMP Trap/Inform• RMON (1,2,3,9 groups)• SDM Template• DHCP/BOOTP Client• Dual Image, Dual Configuration• CPU Monitoring• Cable Diagnostics• EEE• SNTP• System Log |
OTHERS | |
---|---|
Certification | CE, FCC, RoHS |
Package Contents | TL-SG2210PPower AdapterInstallation GuideRubber Feet |
System Requirements | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux. |
Environment | Operating Temperature: 0℃~40℃ (32℉~104℉); Storage Temperature: -40℃~70℃ (-40℉~158℉) Operating Humidity: 10%~90% non-condensing Storage Humidity: 5%~90% non-condensing |
*PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.
**Zero-Touch Provisioning requires the use of Omada Cloud-Based Controller.