JetStream 24-Port Gigabit L2 Managed Switch with 4 SFP Slots

  • Full Gigabit Ports: 24× gigabit RJ45 ports and 4× gigabit SFP Slots provide high-speed connections.
  • Integrated into Omada SDN: Zero-Touch Provisioning (ZTP)*, Centralized Cloud Management, and Intelligent Monitoring.
  • Centralized Management: Cloud access and Omada app for ultra convenience and easy management.
  • Static Routing: Helps route internal traffic for more efficient use of network resources.
  • Robust Security Strategies: IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm control, DHCP Snooping, 802.1X, Radius Authentication, and more.
  • Optimize Voice and Video Applications: L2/L3/L4 QoS and IGMP snooping.
  • Standalone Management: Web, CLI (Console Port, Telnet, SSH), SNMP, RMON, and Dual Image bring powerful management capabilities
  • What is Omada Cloud SDN?

 

Mais >

Casos Relacionados

  • Texas Roadhouse

    Omada Helps Texas Roadhouse Build a Reliable Network

    Texas Roadhouse

    Omada Helps Texas Roadhouse Build a Reliable Network

    “The newly updated network infrastructure is performing well, and Texas Roadhouse is experiencing no crashes with their POS systems as they were previously, which saves a lot of unnecessary cost causing by POS system crush before.”
  • PGL ESPORTS

    TP-Link Provides Reliable Networking Service for PGL Major Kraków

    PGL ESPORTS

    TP-Link Provides Reliable Networking Service for PGL Major Kraków

    “The TP-Link hardware performed as expected and allowed us to deploy a complex network in a short amount of time, with a minimal amount of troubleshooting required.” —Vlad Rosca, PGL Technical Director
  • East European Comic Con

    TP-Link Provides Internet Access for East European Comic Con for the Fourth Year Running

    East European Comic Con

    TP-Link Provides Internet Access for East European Comic Con for the Fourth Year Running

    “TP-Link Romania have provided a high-quality service and the right equipment to meet our requirements in each of the projects we have worked on together. EECC2017 was their toughest challenge so far and they passed with flying colors.” —Marius Radu, EECC Gaming Director
  • TV Skyline

    Omada Offers TV Skyline Reliable Data Transfers and Failure Safety for Live Broadcasting

    TV Skyline

    Omada Offers TV Skyline Reliable Data Transfers and Failure Safety for Live Broadcasting

    “TP-Link gave excellent technical support regarding the configuration of V-LANs and LACP, i.e. cable bundling. It is especially great that we have a personal contact person for all questions regarding the technology.” —Laurent Schiltz, technical manager at TV Skyline
CARACTERÍSTICAS DE HARDWARE
Interface • 24× 10/100/1000 Mbps RJ45 Ports
• 4× Gigabit SFP Slots
• 1× RJ45 Console Port
• 1× Micro-USB Console Port
Quantidade de ventoinhas Fanless
Fonte de alimentação 100-240 V AC~50/60 Hz
Dimensões (L x P x A) 17.3 × 7.1 × 1.7 in (440 × 180 × 44 mm)
Mounting Rack Mountable
Max Power Consumption 19.22 W (110 V/60 Hz)
Max Heat Dissipation 65.58 BTU/h (110 V/60 Hz)
PERFORMANCE
Switching Capacity 56 Gbps
Packet Forwarding Rate 41.66 Mpps
MAC Address Table 8K
Jumbo Frame 9 KB
FUNCIONALIDADES SOFTWARE
Quality of Service • 8 priority queues
• 802.1p CoS/DSCP priority
• Queue scheduling
- SP (Strict Priority)
- WRR (Weighted Round Robin)
- SP+WRR
• Bandwidth Control
- Port/Flow based Rating Limiting
• Smoother Performance
• Action for Flows
- Mirror (to supported interface)
- Redirect (to supported interface)
- Rate Limit
- QoS Remark
L3 Features • 16 IPv4/IPv6 Interfaces
• Static Routing
- 48 static routes
• Static ARP
• 316 ARP Entries
• Proxy ARP
• Gratuitous ARP
• DHCP Server
• DHCP Relay
• DHCP L2 Relay
L2 and L2+ Features • Link Aggregation
- Static link aggregation
- 802.3ad LACP
- Up to 8 aggregation groups and up to 8 ports per group
• Spanning Tree Protocol
- 802.1d STP
- 802.1w RSTP
- 802.1s MSTP
- STP Security: TC Protect, BPDU Filter, BPDU Protect, Root Protect, Loop Protect
• Loopback Detection
- Port-based
- VLAN based
• Flow Control
- 802.3x Flow Control
- HOL Blocking Prevention
• Mirroring
- Port Mirroring
- CPU Mirroring
- One-to-One
- Many-to-One
- Tx/Rx/Both
L2 Multicast • Supports 511 (IPv4, IPv6) IGMP groups
• IGMP Snooping
- IGMP v1/v2/v3 Snooping
- Fast Leave
- IGMP Snooping Querier
- IGMP Authentication
• IGMP Authentication
• MVR
• MLD Snooping
- MLD v1/v2 Snooping
- Fast Leave
- MLD Snooping Querier
- Static Group Config
- Limited IP Multicast
• Multicast Filtering: 256 profiles and 16 entries per profile
Advanced Features • Support Omada Hardware Controller (OC200/OC300), Software Controller, Cloud-Based Controller
• Automatic Device Discovery
• Batch Configuration
• Batch Firmware Upgrading
• Intelligent Network Monitoring
• Abnormal Event Warnings
• Unified Configuration
• Reboot Schedule
• ZTP (Zero-Touch Provisioning)*
VLAN • VLAN Group
- Max 4K VLAN Groups
• 802.1q Tagged VLAN
• MAC VLAN: 12 Entries
• Protocol VLAN: Protocol Template 16, Protocol VLAN 16
• GVRP
• VLAN VPN (QinQ)
- Port-Based QinQ
- Selective QinQ
• Voice VLAN
Access Control List • Time-based ACL
• MAC ACL
- Source MAC
- Destination MAC
- VLAN ID
- User Priority
- Ether Type
• IP ACL
- Source IP
- Destination IP
- Fragment
- IP Protocol
- TCP Flag
- TCP/UDP Port
- DSCP/IP TOS
- User Priority
• Combined ACL
• Packet Content ACL
• IPv6 ACL
• Policy
- Mirroring
- Redirect
- Rate Limit
- QoS Remark
• ACL apply to Port/VLAN
Security • IP-MAC-Port Binding
- DHCP Snooping
- ARP Inspection
- IPv4 Source Guard
• IPv6-MAC-Port Binding
- DHCPv6 Snooping
- ND Detection
- IPv6 Source Guard
• DoS Defend
• Static/Dynamic Port Security
- Up to 64 MAC addresses per port
• Broadcast/Multicast/Unicast Storm Control
- kbps/ratio/pps control mode
• IP/Port/MAC based access control
• 802.1X
- Port based authentication
- Mac based authentication
- VLAN Assignment
- MAB
- Guest VLAN
- Support Radius authentication and
accountability
• AAA (including TACACS+)
• Port Isolation
• Secure web management through HTTPS with SSLv3/TLS 1.2
• Secure Command Line Interface (CLI) management with SSHv1/SSHv2
IPv6 • IPv6 Dual IPv4/IPv6
• Multicast Listener Discovery (MLD) Snooping
• IPv6 ACL
• IPv6 Interface
• Static IPv6 Routing
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP) version 6
• TCPv6/UDPv6
• IPv6 applications
- DHCPv6 Client
- Ping6
- Tracert6
- Telnet (v6)
- IPv6 SNMP
- IPv6 SSH
- IPv6 SSL
- Http/Https
- IPv6 TFTP
Gestão • Web-based GUI
• Command Line Interface (CLI) through console port, telnet
• SNMPv1/v2c/v3
- Trap/Inform
- RMON (1, 2, 3, 9 groups)
• SDM Template
• DHCP/BOOTP Client
• 802.1ab LLDP/LLDP-MED
• DHCP AutoInstall
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• EEE
• Password Recovery
• SNTP
• System Log
MIBs • MIB II (RFC1213)
• Bridge MIB (RFC1493)
• P/Q-Bridge MIB (RFC2674)
• Radius Accounting Client MIB (RFC2620)
• Radius Authentication Client MIB (RFC2618)
• Remote Ping, Traceroute MIB (RFC2925)
• Support TP-Link private MIBs
• RMON MIB(RFC1757, rmon 1,2,3,9)
GESTÃO
Omada App Yes. Requiring the use of OC300, OC200, or Omada Software Controller.
Centralized Management • Omada Hardware Controller (OC300)
• Omada Hardware Controller (OC200)
• Omada Software Controller
Cloud Access Yes. Requiring the use of OC300, OC200, or Omada Software Controller.
Management Features • Web-based GUI
• Command Line Interface (CLI) through console port, telnet
• SNMPv1/v2c/v3
- Trap/Inform
- RMON (1, 2, 3, 9 groups)
• SDM Template
• DHCP/BOOTP Client
• 802.1ab LLDP/LLDP-MED
• DHCP AutoInstall
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• EEE
• Password Recovery
• SNTP
• System Log
OUTROS
Certificações CE, FCC, RoHS
Conteúdo da embalagem • TL-SG3428 Switch
• Power Cord
• Quick Installation Guide
• Rackmount Kit
• Rubber Feet
Requisitos de Sistema Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
Temperatura e Humidade • Operating Temperature: 0–45 ℃ (32–113 ℉);
• Storage Temperature: -40–70 ℃ (-40–158 ℉)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing

*Zero-Touch Provisioning requires the use of Omada Cloud-Based Controller.