SG2005P-PD

Nou

Omada 5-Port Gigabit Smart Switch with 1-Port PoE++ In and 4-Port PoE+ Out

  • Up to 200 m PoE Distance: Standard PoE Passthrough to doubles PoE source-to-device transmission distance from 100 m (328 ft) to 200 m (656 ft) without losing gigabit speeds, perfect for long-range surveillance cameras and access points.*
  • 1-Port Gigabit PoE++ In and 4-Port PoE+ Out: Supports up to 64 W / 44 W / 19 W/ 6 W PoE budget output when powered by 802.3bt Type 4 (90 W), 802.3bt Type 3 (60 W), 802.3at, and 802.3af PoE, respectively.**
  • Outdoor Weatherproof: IP55 waterproof, dustproof, and UV-resistant enclosure. Operation temperatures of -40 to 60 °C and 4KV lightning protection further ensure stable operation against harsh outdoor conditions.
  • Easy Installation: Easy to mount to a wall or pole with the provided mounting kits to flexibly fit your needs.
  • Centralized Cloud Management: Integrates into Omada SDN for cloud access, remote management, and multi-site management.
  • Value-Added Features Foster Touchpoint Experiences: Static Routing, Access Control List (ACL), QoS, and VLAN.

Learn more about TP-Link PoE technology >

Learn more about Omada Cloud SDN>​

PoE-Powered PoE Switch for
Simplified Outdoor Network Deployment

Omada 5-Port Gigabit Smart Switch with 1-Port PoE++ In and 4-Port PoE+ Out

SG2005P-PD

  •  

    Powered by
    PoE++/PoE+/PoE

  •  

    Max 64 W PoE Budget with
    4 PoE+ Output Ports**

  •  

    Double the PoE Distance up to 200 m without Losing Gigabit Speeds*

  •  

    Full Gigabit Ports

  •  

    Easy Installation with
    Pole-Mounting / Wall-Mounting

  •  

    Waterproof and
    UV-Resistant Casing

  •  

    Centralized and
    Multi-Site Management

  •  

    Static Routing

Standard PoE Passthrough to Extend Power and Data Transmission Distance up to 200 m Without Losing Gigabit Speeds

Eliminate mains access location limits and transmit data and power through one cable, simplifying installation and cutting deployment costs. Doubles PoE source-to-device connection distance from 100 m (328 ft) to 200 m (656 ft), perfect for long-range surveillance cameras and access points.*

Web Browser

Omada App

Cloud Access

Omada VPN Router

PoE++ Injector

SG2005P-PD

Access point

IP Camera

Omada Hardware Controller

Or

Omada Software Controller

PoE++ In

PoE+ Out

Up to 200m PoE Distance

Data Only

Data and Power (Up to 100m)

One Gigabit PoE++ In Port and Four Gigabit PoE+ Out Ports

Supports up to 64 W / 44 W / 19 W/ 6 W PoE budget output when powered by 802.3bt Type 4 (90 W), 802.3bt Type 3 (60 W), 802.3at, and 802.3af PoE, respectively.** The PoE-PD switch automatically detects the required PoE power for your devices and protects your non-PoE equipment from being damaged.

4× Gigabit 802.3at/af PoE Output; Up to
30 W per Port and Max 64W in Total

1× Gigabit 802.3bt/at/af PoE Input; Powered by a PoE++ Switch or PoE++ Injector

Outdoor AP

Outdoor AP

IP Camera

IP Camera

Specially Designed Weatherproof Enclosure for Outdoors

Rated as IP55 during Ingress Protection testing, a resilient weatherproof enclosure protects the switch against harsh outdoor conditions.

  •  

    Waterproof Enclosure

  •  

    No Ingress of Dust


  •  

    Operation Temperature of -40 to 60 °C

  •  

    UV-Resistant Casing

  •  

    4KV Lightning Protection

Easy Installation to Flexibly Fit Your Needs

Easy to mount to a wall or pole with the provided mounting kits. Its compact design allows you to place the switch flexibly, such as in an outdoor Junction Box.

  • Mount to a Pole

    Mount to a Pole

  • Mount to a Wall

    Mount to a Wall

Value-Added Features Foster Touchpoint Experiences

  •  

    Static Routing

    Helps route internal traffic for more efficient use of network resources.

  •  

    Access Control List (ACL)

    ACL serves as a virtual admin, allowing all connected devices to obtain data in accordance with user-defined network rules and help you create the network regulations you need.

  •  

    QoS for Lag-Free Experiences

    Designate the priority of traffic based on QoS, ensuring latency-sensitive applications, like voice and video, remain clear and lag-free.

  •  

    VLAN for Security and Flexible Management

    VLAN allows for logical grouping management of devices in different physical LANs, improving information security and reducing data congestion.

Software Defined Networking (SDN) with Cloud Access

Omada’s Software Defined Networking (SDN) platform integrates network devices, including access points, switches, and gateways, providing 100% centralized cloud management. Omada creates a highly scalable network—all controlled from a single interface.

  •  

    Hassle-Free Cloud or
    On-Premises Controllers

  •  

    Multi-Site Cloud
    Management

  •  

    Zero-Touch
    Provisioning (ZTP)***

  •  

    Intelligent
    Monitoring

CARACTERISTICI HARDWARE
Standarde și Protocoale IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.1x
Interfață • 1× 10/100/1000 Mbps RJ45 PoE In Ports (compliance with 802.3af/at/bt)
• 4× 10/100/1000 Mbps RJ45 PoE Out Ports (compliance with 802.3af/at PoE)
Rețea media • 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m)
• 100BASE-TX/1000Base-T: UTP category 5, 5e or above cable (maximum 100m)
Număr ventilatoare Fanless
Alimentator Obtain Power from 802.3af/at/bt PoE Source
Porturi (RJ45) PoE • PoE In Port: Port 5, Compliance with 802.3af/at/bt
• PoE Out Ports: Ports 1-4, compliance with 802.3af/at PoE
• PoE Power Budget:
-64 W when powered by 802.3bt Type 4 (90 W)
-44 W when powered by 802.3bt Type 3 (60 W)
-19 W when powered by 802.3at
-6 W when powered by 802.3af
Dimensiuni (L x l x H) 3.9 × 1.5 × 6.7 in (100 × 38.5 × 170 mm)
Consum maxim 71.5 W (when powered by 802.3bt Type 4 (90 W))
Max Heat Dissipation 243.99 BTU/hr (when powered by 802.3bt Type 4 (90 W))
Performanță
Switching Capacity 10 Gbps
Packet Forwarding Rate 7.44 Mpps
Tabelă Adrese MAC 8k
Packet Buffer Memory 4.1 Mbit
Jumbo Frame 9 KB
Caracteristici Software
Calitatea Serviciului • 802.1p CoS/DSCP priority
• 8 priority queues
• Priority Schedule Mode
- SP (Strict Priority)
- WRR (Weighted Round Robin)
• Queue Weight Config
• Bandwidth Control
- Port/Flow-based Rating Limit
• Smoother Performance
• Storm Control
- Multiple Control Modes(kbps/ratio)
- Broadcast/Multicast/Unknown-Unicast Control
Caracteristici L2 și L2+ • 32 IP Interfaces
- Support IPv4/IPv6 Interface
• Static Routing
- 32 IPv4/IPv6 Static Routes
• DHCP Server
• DHCP Relay
- DHCP Interface Relay
- DHCP VLAN Relay
• DHCP L2 Relay
• Static ARP
• Proxy ARP
• Gratuitous ARP
• Link Aggregation
- Static link aggregation
- 802.3ad LACP
- Up to 8 aggregation groups and up to 8 ports
per group
• Spanning Tree Protocol
- 802.1D STP
- 802.1w RSTP
- 802.1s MSTP
- STP Security: TC Protect, BPDU Filter/Protect,
Root Protect
• Loopback Detection
• Flow Control
- 802.3x Flow Control
• Mirroring
- Port Mirroring
- CPU Mirroring
- One-to-One
- Many-to-One
- Flow-Based
- Ingress/Egress/Both
• Device Link Detect Protocol (DLDP)
• 802.1ab LLDP/ LLDP-MED
L2 Multicast • 511 IPv4, IPv6 shared multicast groups
• IGMP Snooping
- IGMP v1/v2/v3 Snooping
- Fast Leave
- IGMP Snooping Querier
- Static Group Config
• Multicast VLAN Registration (MVR)
• Multicast Filtering
• MLD Snooping
- MLD v1/v2 Snooping
- Fast Leave
- MLD Snooping Querier
- Static Group Config
• Limited IP Multicast (256 profiles and 16 entries per profile)
Caracteristici Avansate • Automatic Device Discovery
• Batch Configuration
• Batch Firmware Upgrading
• Intelligent Network Monitoring
• Abnormal Event Warnings
• Unified Configuration
• Reboot Schedule
IPv6 Support • IPv6 Dual IPv4/IPv6
• Multicast Listener Discovery (MLD) Snooping
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP) version 6
• TCPv6/UDPv6
• IPv6 applications
- DHCPv6 Client
- Ping6
- Tracert6
- Telnet (v6)
- IPv6 SNMP
- IPv6 SSH
- IPv6 SSL
- Http/Https
- IPv6 TFTP
VLAN • VLAN Group
- Max. 4K VLAN Groups
• 802.1Q tag VLAN
• MAC VLAN: 12 Entries
• Protocol VLAN
• GVRP
• Voice VLAN
Listă Control Acces • Support up to 230 entries
• Time-Range
- Time Slice
- Week Time-Range
- Absolute Time-Range
- Holiday
• Time-based ACL
• MAC ACL
- Source MAC
- Destination MAC
- VLAN ID
- User Priority
- Ether Type
• IP ACL
- Source IP
- Destination IP
- IP Protocol
- TCP Flag
- TCP/UDP Source Port
- TCP/UDP Destination Port
- DSCP/IP TOS
• IPv6 ACL
• Combined ACL
• Rule Operation
- Permit/Deny
• Policy Action
- Mirror
- Rate Limit
- Redirect
- QoS Remark
• ACL Rules Binding
- Port Binding
- VLAN Binding
• Actions for flows
- Mirror (to supported interface)
- Redirect (to supported interface)
- Rate Limit
- QoS Remark
Securitate • AAA
• 802.1X
- Port-based authentication
- MAC (Host) based authentication
- Authentication Method includes PAP/EAP-MD5
- MAB
- Guest VLAN
- Support Radius authentication and accountability
• IP/IPv6-MAC Binding
- 512 Binding Entries
- DHCP Snooping
- DHCPv6 Snooping
- ARP Inspection
- ND Detection
• IP Source Guard
- 253 Entries
- Source IP+Source MAC
• IPv6 Source Guard
- 183 Entries
- Source IPv6 Address+Source MAC
• DoS Defend
• Static/Dynamic/Permanent Port Security
- Up to 64 MAC addresses per port
• Broadcast/Multicast/Unicast Storm Control
- kbps/ratio control mode
• Port Isolation
• Secure web management through HTTPS with SSLv3/TLS 1.2
• Secure Command Line Interface (CLI) management with SSHv1/SSHv2
• IP/Port/MAC-based access control
MIBs • MIB II (RFC1213)
• Bridge MIB (RFC1493)
• P/Q-Bridge MIB (RFC2674)
• Radius Accounting Client MIB (RFC2620)
• Radius Authentication Client MIB (RFC2618)
• Remote Ping, Traceroute MIB (RFC2925)
• Support TP-Link private MIBs
• RMON MIB(RFC1757, rmon 1,2,3,9)
MANAGEMENT
Omada App Yes, through
• Omada Cloud-Based Controller
• Omada Hardware Controller
• Omada Software Controller
Centralized Management • Omada Cloud-Based Controller
• Omada Hardware Controller
• Omada Software Controller
Cloud Access Yes, through
• Omada Cloud-Based Controller
• Omada Hardware Controller
• Omada Software Controller
Zero-Touch Provisioning Yes. Requiring the use of Omada Cloud-Based Controller.
Management Features • Web-based GUI
• Command Line Interface (CLI) through telnet
• SNMPv1/v2c/v3
• SNMP Trap/Inform
• RMON (1,2,3,9 groups)
• SDM Template
• DHCP/BOOTP Client
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• EEE
• SNTP
• System Log
Altele
Certificări CE, FCC, RoHS
Conținut Pachet • SG2005P-PD
• Mounting Kits
• Installation Guide
Cerințe de sistem Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
Mediu • Operating Temperature: -40 to 60 °C (-40 to 140 °F)
• Storage Temperature: -40 °C to 70 °C (-40 °F to 158 °F)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing

*The actual transmission distance may vary due to the power consumption of PoE-powered devices or the cable quality and type.

**PoE budget calculations are based on laboratory testing. The actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.

***Zero-Touch Provisioning requires the use of Omada Cloud-Based Controller. Note that TL-SG2008P v2 doesn't support Omada Cloud-Based Controller. Go to https://www.tp-link.com/en/omada-cloud-based-controller/product-list/ to confirm which models are compatible with Omada Cloud-Based Controller.

Protection against lightning may be achieved through proper product setup, grounding, and cable shielding. Refer to the instruction manual and consult an IT professional to assist with setting up this product.

From United States?

Get products, events and services for your region.