JetStream 28-Port Gigabit Smart Switch with 24-Port PoE+

  • 250 W PoE Budget: 24× 802.3at/af-compliant PoE+ ports with a total power supply of 250 W*.
  • Full Gigabit Ports: 24× gigabit PoE+ ports and 4× gigabit SFP Slots provide high-speed connections.
  • Integrated into Omada SDN: Zero-Touch Provisioning (ZTP)**, Centralized Cloud Management, and Intelligent Monitoring.
  • Centralized Management: Cloud access and Omada app for ultra convenience and easy management.
  • Static Routing: Helps route internal traffic for more efficient use of network resources.
  • Robust Security Strategies: IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm control, DHCP Snooping, 802.1X, Radius Authentication, and more.
  • Optimize Voice and Video Applications: L2/L3/L4 QoS and IGMP snooping.
  • IPv6: IPv6 support with dual IPv4/IPv6 stack, MLD snooping, IPv6 neighbor discovery.

Learn more about TP-Link PoE technology >

 

Learn more about Omada Cloud SDN>​

  • What is Omada Cloud SDN?

  • Introducing TP-Link PoE Switches

TP-Link | Omada Centralized Management

Realize More Possibilities with Omada

JetStream 28-Port Gigabit Smart Switch with 24-Port PoE+

TL-SG2428P

  •  

    Centralized Cloud Management

    Omada SDN Platform Integration

  •  

    Advanced L2+ Features

    L2/L3/L4 QoS, ACL, Static Routing and More

  •  

    Abundant Security Strategies

    LAN Area Investment Protection

  •  

    PoE+ Output

    24 PoE+ Ports with Total 250 W Power Budget*

Software Defined Networking (SDN) with Cloud Access

Omada’s Software Defined Networking (SDN) platform integrates network devices, including access points, switches and gateways, providing 100% centralized cloud management. Omada creates a highly scalable network—all controlled from a single interface. Seamless wireless and wired connections are provided, ideal for use in hospitality, education, retail, offices, and more.

JetStream Switches Omada Routers Omada Access Points Wi-Fi 6 Celling
Mount
Wall
Plate
Outdoor Unified Management Interface Controllers Cloud Access Cloud
เพิ่มเติม >

กรณีที่เกี่ยวข้อง

HARDWARE FEATURES
Standards and Protocols IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.3az, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.1x
Interface • 24× 10/100/1000 Mbps RJ45 Ports (Auto Negotiation/Auto MDI/MDIX)
• 4× Gigabit SFP Slots
Network Media • 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m)
• 100BASE-TX/1000Base-T: UTP category 5, 5e or above cable (maximum 100m)
• 1000BASE-X: MMF, SMF
Fan Quantity 2
Power Supply 100-240V AC, 50/60Hz
PoE Ports (RJ45) • Standard: 802.3at/af compliant
• PoE+ Ports: 24 Ports
• PoE Power Budget: 250 W*
Dimensions ( W x D x H ) 17.3 × 8.7 × 1.73 in (440 × 220 × 44 mm)
Mounting Rack Mountable
Max Power Consumption • V1: 308.6 W (110V/60Hz with 250 W PD connected); 32.1 W (110 V/ 60 Hz with no PD connected)
• V2: 294.7 W (220 V/50 Hz) (with 250 W PD connected)
• V3: 291.9 W (110V/60Hz) (with 250 W PD connected)
• V4: 306.9 W (110V/60Hz) (with 250 W PD connected)
Max Heat Dissipation • V1: 1052.94 BTU/h (with 250 W PD connected); 109.53 BTU/h (with no PD connected)
• V2: 1005.66 BTU/hr (220V/50 Hz) (with 250 W PD connected)
• V3: 996.01 BTU/hr (110V/60Hz) (with 250 W PD connected)
• V4: 1047.30 BTU/hr (110V/60 Hz) (with 250 W PD connected)
PERFORMANCE
Switching Capacity 56 Gbps
Packet Forwarding Rate 41.7 Mpps
MAC Address Table • V1, V2, V4 and above: 8K
• V3: 16K
Packet Buffer Memory 4.1 Mbit
Jumbo Frame 9 KB
SOFTWARE FEATURES
Quality of Service • 802.1p CoS/DSCP priority
• 8 priority queues
• Priority Schedule Mode
- SP (Strict Priority)
- WRR (Weighted Round Robin)
• Queue Weight Config
• Bandwidth Control
- Port/Flow based Rating Limit
• Smoother Performance
• Storm Control
- Multiple Control Modes(kbps/ratio)
- Broadcast/Multicast/Unknown-Unicast Control
L2 and L2+ Features • 16 IP Interfaces
- Support IPv4/IPv6 Interface
• Static Routing
- 32 IPv4/IPv6 Static Routes
• DHCP Server
• DHCP Relay
- DHCP Interface Relay
- DHCP VLAN Relay
• DHCP L2 Relay
• Static ARP
• Proxy ARP
• Gratuitous ARP
• Link Aggregation
- Static link aggregation
- 802.3ad LACP
- Up to 8 aggregation groups and up to 8 ports
per group
• Spanning Tree Protocol
- 802.1D STP
- 802.1w RSTP
- 802.1s MSTP
- STP Security: TC Protect, BPDU Filter/Protect,
Root Protect
• Loopback Detection
• Flow Control
- 802.3x Flow Control
• Mirroring
- Port Mirroring
- CPU Mirroring
- One-to-One
- Many-to-One
- Flow-Based
- Ingress/Egress/Both
• Device Link Detect Protocol (DLDP)
• 802.1ab LLDP/ LLDP-MED
Advanced Features • Automatic Device Discovery
• Batch Configuration
• Batch Firmware Upgrading
• Intelligent Network Monitoring
• Abnormal Event Warnings
• Unified Configuration
• Reboot Schedule
VLAN • VLAN Group
- Max. 4K VLAN Groups
• 802.1Q tag VLAN
• MAC VLAN: 12 Entries
• Protocol VLAN
• GVRP
• Voice VLAN
Access Control List • Support up to 230 entries
• Time-Range
- Time Slice
- Week Time-Range
- Absolute Time-Range
- Holiday
• Time-based ACL
• MAC ACL
- Source MAC
- Destination MAC
- VLAN ID
- User Priority
- Ether Type
• IP ACL
- Source IP
- Destination IP
- IP Protocol
- TCP Flag
- TCP/UDP Source Port
- TCP/UDP Destination Port
- DSCP/IP TOS
• IPv6 ACL
• Combined ACL
• Rule Operation
- Permit/Deny
• Policy Action
- Mirror
- Rate Limit
- Redirect
- QoS Remark
• ACL Rules Binding
- Port Binding
- VLAN Binding
• Actions for flows
- Mirror (to supported interface)
- Redirect (to supported interface)
- Rate Limit
- QoS Remark
Security • AAA
• 802.1X
- Port based authentication
- MAC (Host) based authentication
- Authentication Method includes PAP/EAP-MD5
- MAB
- Guest VLAN
- Support Radius authentication and
accountability
• IP/IPv6-MAC Binding
- 512 Binding Entries
- DHCP Snooping
- DHCPv6 Snooping
- ARP Inspection
- ND Detection
• IP Source Guard
- 253 Entries
- Source IP+Source MAC
• IPv6 Source Guard
- 183 Entries
- Source IPv6 Address+Source MAC
• DoS Defend
• Static/Dynamic/Permanent Port Security
- Up to 64 MAC addresses per port
• Broadcast/Multicast/Unicast Storm Control
- kbps/ratio control mode
• Port Isolation
• Secure web management through HTTPS with
SSLv3/TLS 1.2
• Secure Command Line Interface (CLI)
management with SSHv1/SSHv2
• IP/Port/MAC based access control
IPv6 • IPv6 Static Routing and ACL
• IPv6 Dual IPv4/IPv6
• IPv6 Interface
• Multicast Listener Discovery (MLD) Snooping
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP)
version 6
• TCPv6/UDPv6
• IPv6 applications
- DHCPv6 Client
- Ping6
- Tracert6
- Telnet(v6)
- IPv6 SNMP
- IPv6 SSH
- IPv6 SSL
- Http/Https
- IPv6 TFTP
MIBs • MIB II (RFC1213)
• Bridge MIB (RFC1493)
• P/Q-Bridge MIB (RFC2674)
• Radius Accounting Client MIB (RFC2620)
• Radius Authentication Client MIB (RFC2618)
• Remote Ping, Traceroute MIB (RFC2925)
• Support TP-Link private MIBs
• RMON MIB(RFC1757, rmon 1,2,3,9)
MANAGEMENT
Omada App Yes, through
• Omada Cloud-Based Controller (Not Supported by TL-SG2428P v2)
• OC300
• OC200
• Omada Software Controller
Centralized Management • Omada Cloud-Based Controller (Not Supported by TL-SG2428P v2)
• Omada Hardware Controller OC300
• Omada Hardware Controller OC200
• Omada Software Controller
Cloud Access Yes, through
• Omada Cloud-Based Controller (Not Supported by TL-SG2428P v2)
• OC300
• OC200
• Omada Software Controller
Zero-Touch Provisioning Yes. Requiring the use of Omada Cloud-Based Controller (Supported by TL-SG2428P v1, v3 and above, while is not supported by TL-SG2428P v2)
Management Features • Web-based GUI
• Command Line Interface (CLI) through telnet
• SNMPv1/v2c/v3
• SNMP Trap/Inform
• RMON (1,2,3,9 groups)
• SDM Template
• DHCP/BOOTP Client
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• EEE
• SNTP
• System Log
OTHERS
Certification CE, FCC, RoHS
Package Contents TL-SG2428P
• Power Cord
• Installation Guide
• Rackmount Kit
• Rubber Feet
System Requirements Microsoft® Windows® XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
Environment • Operating Temperature: 0–50 ℃ (32–122 ℉);
• Storage Temperature: -40–70 ℃ (-40–158 ℉)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing

*PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.

**Zero-Touch Provisioning requires the use of Omada Cloud-Based Controller. Note that TL-SG2428P v2 doesn't support Omada Cloud-Based Controller. Please go to Omada Cloud-Based Controller Product List to find all the models supported by Omada Cloud-Based Controller.