SG6654XHP
ผลิตภัณฑ์ใหม่Omada 48-Port Gigabit Stackable L3 Managed PoE+ Switch with 6 10G Slots
- 48× Gigabit RJ45 PoE+ ports
- 6× 10 Gbps SFP+ slots
- Up to 1440 W total PoE budget*
- Physical Stacking for built-in redundancy and performance
- L3 features: RIP, OSPF, ECMP, VRRP, PIM-DM, DHCP Server/Relay
- Security Strategies: ACL, Port Security, DoS Defend, 802.1X
- Highly Available with two field-replaceable power supplies,** VRRP, and ERPS
- Centralized cloud management via the Omada SDN controller
- Standalone management via web, CLI, SNMP, and RMON
What This Product Does
Omada SG6654XHP, an advanced L3 managed PoE+ switch, is crafted for convergence layer requirements with features like L3 routing, rapid 10 Gbps wired connectivity, stacking, and redundant power supplies. It offers an impressive 1440 W PoE budget,* 48× gigabit RJ45 PoE+ ports, 6× 10 Gbps SFP+ slots, and physical stacking. Combined with centralized management, strong security, and comprehensive management features, SG6654XHP is an ideal, reliable network solution for SMBs, enterprises, and ISPs.
IEEE 802.3at/af-compliant Power over Ethernet
48× IEEE 802.3at/af-compliant PoE ports supply up to 1440 W total power to 802.3at and 802.3af devices,* with each port supplying up to 30 W power. Set up wireless access points, surveillance cameras, IP phones, and other PoE devices quickly and easily, without the hassle and cost of installing power cabling.
High-speed Connectivity and Powerful Stacking
48 gigabit RJ45 ports and 6× 10 Gbps SFP+ slots provide up to 216 Gbps switching capacity per unit. Up to 4 units of physical stacking with up to 864 Gbps switching capacity empower the networking structure with built-in redundancy and performance.
Abundant Layer 3 Capabilities
Comes with abundant Layer 3 routing protocols that support a scalable network. Static Routing, RIP, OSPF, ECMP, VRRP, DHCP Server, and DHCP Relay are supported. PIM-DM multicast routing protocol guarantees efficient routing for multicast groups.
Highly Available
Optional field-replaceable and hot-swappable redundant power supplies and VRRP make it an ideal choice for reliable networking architecture.** ERPS supports rapid protection and recovery in a ring topology.
Enhanced Security Functions
Defend against a range of network threats with ACL support (IPv4 & IPv6), Dynamic ARP Inspection, IEEE 802.1X, MAB, Port Security, and Secure Shell.
Omada SDN
Integration into the Omada system brings centralized cloud management and a series of management features such as Zero-Touch Provisioning (ZTP).‡ The Omada Software Defined Networking (SDN) platform integrates network devices, including access points, switches, and routers, providing 100% centralized cloud management—all controlled from a single interface.
Apart from the ability to be centrally managed via the web or the Omada app, SG6654XHP is also easy to manage via an intuitive web-based Graphical User Interface (GUI) or an industry-standard Command Line Interface (CLI). For both management methods, traffic is protected through SSL or SSH encryption. SNMP (v1/v2c/v3) and RMON support enable the switch to be polled for valuable status information and to send traps for abnormal events.
HARDWARE FEATURES | |
---|---|
Interface | • 48× 10/100/1000 Mbps PoE+ RJ45 Ports• 6× 10G SFP+ Slots• 2× USB 2.0 Ports• 1× RJ45 Console Port• 1× USB Type-C Console Port• 1× RJ45 Management Port |
Fan Quantity | Four Field-replaceable and Hot-swappable Fans |
Power Supply | Two Field-replaceable and Hot-swappable Power Supply Modules** (100–240 VAC, 50/60 Hz)**Shipping with one PSM900-AC module by default, and another field-replaceable redundant power supply requires purchasing separately. |
PoE Ports (RJ45) | • Standard: 802.3at/af compliant• PoE+ Ports: 48 Ports, up to 30 W per port• PoE Power Budget: up to 1440 W**The total PoE budget varies with the power supply modules. |
Dimensions ( W x D x H ) | 17.3 × 16.5 × 1.7 in (440 × 420 × 44 mm) |
Mounting | Rackmountable |
Max Power Consumption | • 67.24 W (110 V/60 Hz) (With no PD connected)• 1767.7 W (110 V/60 Hz) (With 1440W PD connected and powered by 2× PSM900-AC) |
Max Heat Dissipation | • 229.29 BTU/hr (110 V/60 Hz) (With no PD connected)• 6,027.86 BTU/hr (110 V/60 Hz) (With 1440W PD connected and powered by 2× PSM900-AC) |
PERFORMANCE | |
---|---|
Switching Capacity | 216 Gbps per Unit |
Stacking | • Stacking Number: 4• Stacking Port: 10G SFP+ Slot (all uplink ports can be used as stacking ports)• Stack Bandwidth: 20 Gbps Per Port (Full-Duplex) |
Packet Forwarding Rate | 160.7 Mpps |
MAC Address Table | 32 K |
Packet Buffer Memory | 3 MB |
Jumbo Frame | 9 KB |
SOFTWARE FEATURES | |
---|---|
Quality of Service | • Class of Service - 8 Queues of Priority - Port Priority - IEEE 802.1p Priority - DSCP Priority - Queue Min-Bandwidth - Schedule Mode (SP, WRR, SP+WRR)• Bandwidth Control - Rate Limit - Storm Control• Voice VLAN • User-Defined OUI • Smoother Performance• Action for Flows - QoS remark (802.1P Remark, DSCP Remark) |
L3 Features | • IP Interfaces:- IPv4: Max 256, IPv6: Max 256• Static Routing- Max 1,024, IPv6: Max 512• Host Route Table: Max 6,100 entries• RIP: Version v1/v2, Max 8,190• OSPF: Version v2/v3; v2: Max 8,190, v3: Max 4,097• VRRP: Version v2/v3, Max 64 groups• ECMP: 256 entries, max 32 ECMP Nexthops per Destination• Static ARP: 512 static entries• Dynamic ARP: 7,680 dynamic entries• Proxy ARP• DHCP Server:- Max 8K IP Pools- Max 1,000 Manual Binding Entries• DHCP Relay:- Relayed Interface- Relayed VLAN |
L2 and L2+ Features | • Link Aggregation• Spanning Tree Protocol• Port-based and VLAN-based Loopback Detection• 802.3x Flow Control• Supports 2,048 IGMP groups• ERPS• Mirroring• RSPAN• MAC Address Table• PIM-DM (IPv4) • Multicast - IGMP Snooping - MLD Snooping - L2 Multicast Table - Fast Leave - Multicast VLAN Registration (MVR) - Static Multicast IP - Multicast Filtering |
Advanced Features | • Automatic Device Discovery†• Batch Configuration†• Batch Firmware Upgrading†• Intelligent Network Monitoring†• Abnormal Event Warnings†• Unified Configuration†• Reboot Schedule†ISP Features:• 802.3ah Ethernet Link OAM • L2PT (Layer 2 Protocol Tunneling) • Device Link Detect Protocol (DLDP)• DDM• sFlow |
VLAN | • Max 4K VLAN Group (802.1q VLAN)• 802.1Q Tagged VLAN• MAC VLAN Entries: 200• Multicast VLAN• Management VLAN• VLAN VPN (QinQ): Max 256 entries• GVRP• Protocol VLAN: Protocol Template 16, Protocol VLAN 12 entries• VLAN VPN• Voice VLAN• Private VLAN |
Security | • Port Isolation• CPU-Defend• ARP Inspection (Dynamic ARP Inspection)• DoS Defend• IP-MAC-Port Binding-1,024 Entries- DHCP Snooping- ARP Inspection- IPv4 Source Guard• IPv6-MAC-Port Binding-1,024 Entries- DHCPv6 Snooping- ND Detection- ND Snooping- IPv6 Source Guard• DHCP Filter• Static/Dynamic Port Security- Up to 64 MAC addresses per port• Broadcast/Multicast/Unknown-unicast Storm Control- kbps/ratio control mode• 802.1X- Port base authentication- Mac base authentication- VLAN Assignment- MAB- Guest VLAN- RADIUS authentication and accountability support• AAA (including TACACS+)• Secure web management through HTTPS with SSLv3/TLS 1.2• Secure Command Line Interface (CLI) management with SSHv2• IP/Port/MAC-based access control |
MANAGEMENT | |
---|---|
Omada App | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
Centralized Management | • Omada Cloud-Based Controller• Omada Hardware Controller• Omada Software Controller |
Cloud Access | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
Zero-Touch Provisioning | Yes. Requiring the use of Omada Cloud-Based Controller. |
Management Features | • Web-based GUI• Command Line Interface (CLI) through console port, telnet• SNMPv1/v2c/v3- Trap/Inform- RMON (1, 2, 3, 9 groups)• SDM Template• DHCP/BOOTP Client• 802.1ab LLDP/LLDP-MED• DHCP Auto Install• Dual Image, Dual Configuration• CPU Monitoring• Cable Diagnostics• Password Recovery• SNTP• System Log• EEE |
OTHERS | |
---|---|
Package Contents | • SG6654XHP Switch• Power Cord• RJ45 Console Cable• Quick Installation Guide• Rackmount Kit• Rubber Feet |
System Requirements | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux. |
Environment | • Operating Temperature: 0–45 ℃ (32–113 ℉);• Storage Temperature: -40–70 ℃ (-40–158 ℉)• Operating Humidity: 10–90% RH non-condensing• Storage Humidity: 5–90% RH non-condensing |
†These functions require the use of the Omada SDN Controller.
‡Zero-Touch Provisioning requires the use of the Omada Cloud-Based Controller. Please go to www.tp-link.com/en/omada-cloud-based-controller/product-list/ to confirm which models are compatible with the Omada Cloud-Based Controller.
*The total PoE budget varies with the power supply modules.
**Ships with one PSM900-AC module by default, and another field-replaceable redundant power supply requires a separate purchase.