EAP615GP-Wall
NuevoOmada AX1800 Wi-Fi 6 Wall Plate GPON Access Point
- Seamless 1.8 Gbps WiFi 6 Speeds: 1201 Mbps on 5 GHz & 574 Mbps on 2.4 GHz†
- 1× GPON Port for High-Speed and Ultra-Range Access
- Ultra-Broadband WiFi 6: MU-MIMO, Seamless Roaming§
- One Fiber for Multiple Services: Wired, Wireless, Voice, VoIP, Data, and HD Video Services
- VoIP Calls: Support multiple VolP accounts and various call features, exceeding traditional landlines
- Easy Use: One-Click Pairing and Automatic Adoption
- Smart O&M: PPSK△ and Multiple Portals§
- Centralized Management: Integrates with the Unified Optical Solution
- Wall-Mounted, AC Powered
-
Integrates into Omada
Optical Networking -
Omada Centralized
Management -
One Fiber,
Multiple Services -
WiFi 6
Gigabit ONU -
Seamless Roaming
& Omada Mesh -
PPSK &
Captive Portal -
One-Click
Easy Setup -
AC Power
Supply
Complete Omada Optical Networking Solution
The Omada Optical Networking Solution delivers enterprise-grade gigabit passive optical networking. It seamlessly integrates essential components such as Omada switches, gateways, OLTs (Optical Line Terminals), and ONUs (Optical Network Units)—perfect for P2MP (point-to-multipoint) environments like hotels and MDUs.
Controller
Controller
Controller
-
Omada Centralized
Management -
Quick, Easy
Adoption -
Easy
Setup -
Complete
Product Types -
Zero-Touch
Provisioning -
Easy
Monitoring
One Fiber, Multiple Services
Connect a fiber optic cable to the EAP615GP-Wall to connect cameras, PCs, and TVs to carry data, voice, wired and wireless internet, HD video, and VoIP services.
ODN
(Splitter)
1× GPON Port
Fiber Optics
Copper Cable
RJ11 Cable
1× FXS RJ11 Port
2× Gigabit Ports
Phone
TV
CCTV
PC
Seamless WiFi 6 Mesh Networking
Leverage GPON WiFi 6 technology for a robust and seamless network experience, delivering speeds up to 1.8 Gbps.*
Omada Mesh and 802.11k/v roaming ensure a consistently smooth and reliable connection.
EAP615GP
-Wall
Roaming
EAP615GP
-Wall
Omada VPN Gateway
Five-Step Installation
1. Detach the faceplate of the junction box with a screwdriver
2. Secure the mounting bracket
3. Connect the AC power cable
AC Power Supply
4. Connect the optical fiber
5. Attach the EAP to the mounting bracket
CARACTERÍSTICAS DE HARDWARE | |
---|---|
Interface | • 1x GPON Port • 1x FXS Port• 2x Gigabit RJ45 Ports |
GPON Interface | • Port Type: SC-APC• Standards and Protocols: ITU-984.x, G.988, Class B+• Data Rate: 2.488 Gbps (Downstream); 1.244 Gbps (Upstream)• Fiber Type: 9/125 um Single mode• Max. Cable Length: 20 km |
Botón | • Reset• LED |
Fuente de alimentación | 100–240V~ 50/60Hz, 0.5A |
Consumo de Poder | 12.2W |
Peso | 320g |
Dimensiones (An x Pr x Al) | 5.6 × 3.4 × 1.5 in (143 × 86 × 37.6 mm) |
Tipo de Antena | Internal Omni• 2.4 GHz: 2× 4 dBi• 5 GHz: 2× 6.5 dBi |
Montaje | Wall Mounting (Kits included) |
CARACTERÍSTICAS INALÁMBRICAS | |
---|---|
Coverage | 50㎡(600ft²)** |
Concurrent Clients | 120+* |
Estándares inalámbricos | IEEE 802.11 a/b/g/n/ac/ax |
Frecuencia | 2.4 GHz and 5 GHz |
Tasa de señal | • 5 GHz: 1201 Mbps†• 2.4 GHz: 574 Mbps |
Funciones inalámbricas | • 2×2 (2.4G & 5G) MU-MIMO‡• HE80 (80 MHz Bandwidth)‡• OFDMA‡• Seamless Roaming §• Multiple SSIDs (16 SSIDs, 8 on each band)• Enable/Disable SSID Broadcast• Enable/Disable Wireless Radio• Guest Network• Automatic Channel Assignment• Beamforming• Rate Limit• Band Steering• Load Balance• Airtime Fairness • Transmit Power Control (Adjust Transmit Power on dBm)• QoS (WMM)• RADIUS Accounting• MAC Authentication• Reboot Schedule• Wireless Schedule and Statistics• Static IP/Dynamic IP |
Seguridad inalámbrica | • Captive Portal Authentication§• Access Control• Wireless Mac Address Filtering• Wireless Isolation Between Clients• VLAN • Rogue AP Detection• 802.1X Support• WPA-Personal/Enterprise, WPA2-Personal/Enterprise, WPA3-Personal/Enterprise |
Poder de transmision | • CE: <20 dBm(2.4 GHz, EIRP)<23 dBm(5 GHz, band1 & band2, EIRP)<24 dBm(5 GHz, band3, EIRP)• FCC: <21 dBm (2.4 GHz)<21 dBm (5 GHz) |
ADMINISTRACIÓN | |
---|---|
Aplicación Omada | Yes |
Gestión centralizada | • Omada Hardware Controller (OC300, OC200)• Omada Software Controller• Omada Cloud-Based Controller |
Acceso a la nube | Yes. Require the use of OC300, OC200, Omada Cloud-Based Controller, or Omada Software Controller. |
Alertas de correo electrónico | Yes |
Control de LED ENCENDIDO / APAGADO | Yes |
Gestión de control de acceso MAC | Yes |
SNMP | v1, v2c, v3 |
Registro del sistema Local / Remote Syslog | System Log |
SSH | Yes |
Gestión basada en web | Yes |
Aprovisionamiento sin intervención | Yes. Require the use of Omada Cloud-Based Controller. |
OTROS | |
---|---|
Certificación | CE, FCC, RoHS, IC |
contenidos del paquete | • EAP615GP-Wall• Wall Mounting Kit• Installation Guide |
Requisitos del sistema | Microsoft Windows XP, Vista, Windows 7, Windows 8, Windows10, Windows11, Linux |
Ambiente | • Operating Temperature: 0–40 ℃ (32–104 ℉)• Storage Temperature: -40–70 ℃ (-40–158 ℉)• Operating Humidity: 10–90% RH non-condensing• Storage Humidity: 5–90% RH non-condensing |
†Maximum wireless signal rates are the physical rates derived from IEEE Standard 802.11 specifications. Actual wireless data throughput and wireless coverage are not guaranteed and will vary as a result of 1) environmental factors, including building materials, physical objects, and obstacles, 2) network conditions, including local interference, volume and density of traffic, product location, network complexity, and network overhead, and 3) client limitations, including rated performance, location, connection, quality, and client condition.
‡Use of WiFi 6 (802.11ax) and its features like MU-MIMO, requires clients to support the corresponding features.
§Seamless Roaming, and Captive Portal require the use of Omada SDN controllers.
△This feature needs to be used with the switch that supports VPN Server. And at the same time, the Omada controller needs to be used with the switch that supports the Cli Template.
*The actual capacity depends on the wireless environment and client traffic and is generally less than the maximum number of client connections.
**Coverage value is calculated based on laboratory testing. Actual coverage is not guaranteed and will vary as a result of client limitations and environmental factors.