SG3428XPP-M2

Nuevo

Omada 24-Port 2.5GBASE-T and 4-Port 10GE SFP+ L2+ Managed Switch with 16-Port PoE+ & 8-Port PoE++

  • 8× 2.5G PoE++ ports (up to 60 W PoE out per port)**
  • 16× 2.5G PoE+ ports (up to 30 W PoE out per port)
  • 4× 10G SFP+ slots
  • 500 W total PoE budget*
  • Centralized cloud management via the web or the Omada app
  • Standalone management via web, CLI, SNMP, and RMON
  • Static Routing helps route internal traffic for higher efficiency
  • VLAN, ACL, QoS, IGMP Snooping, OAM, and DDM
  • ERPS supports rapid protection and recovery in a ring topology

Learn more about Omada PoE technology >

Learn more about Omada Cloud SDN>​

Learn more about Omada Multi-Gig technology >

 

TP-Link | Omada POE

Omada 24-Port 2.5GBASE-T
and 4-Port 10GE SFP+ L2+
Managed Switch with 16-Port
PoE+ & 8-Port PoE++

SG3428XPP-M2

  •  

    24× 2.5 Gbps RJ45 Ports
    (8× PoE++, 16× PoE+)

  •  

    4× 10 Gbps
    SFP+ Slots

  •  

    Centralized
    Management

  •  

    Omada
    App


  •  

    500 W Total PoE Budget (Max
    60 W for Each PoE++ Port)*

  •  

    Zero-Touch
    Provisioning

  •  

    Ethernet Ring
    Protection Switching

  •  

    Static
    Routing

Empowering the Real WiFi 6 and WiFi 7 with 2.5G PoE++ / PoE+ Ports

  • 8× 2.5 Gbps

    PoE++

    RJ45 Ports

  • Up to

    60W

    PoE per PoE++ Port

  • 16× 2.5 Gbps

    PoE+

    RJ45 Ports

  • Total

    500W

    PoE Power Budget*

 
  •  

    Access
    Points

  •  

    PTZ HD IP Cameras
    with Heaters

  •  

    Smart Building
    Lighting

  •  

    Audio
    System

  •  

    2.5G
    NAS/Server

  •  

    Workstation
     

Easily Build a Whole 10G Multi-gigabit Network

Software Defined Networking (SDN) with Cloud Access

Remotely manage your access points, switches, and gateways across multiple sites all from a single interface.

Ceiling Mount AP
Wall Plate AP
Outdoor AP
Omada PoE Switch
Omada VPN Gateway
Cloud Access
On-premises Controllers
Omada Hardware
Controller
Or
Omada Software
Controller
Or
Omada Cloud-Based
Controller
(Subscription Required)
Internet
Web Browser
Omada App

CARACTERÍSTICAS DE HARDWARE
Interface • 24× 2.5 Gbps RJ45 Ports (8× PoE++, 16× PoE+)
• 4× 10G SFP+ Slots
• 1× RJ45 Console Port
• 1× Micro-USB Console Port
Cantidad de ventiladores 3
Bloqueo de seguridad física
Fuente de alimentación 100-240 V AC~50/60 Hz
PoE Ports (RJ45) • Standard: 802.3bt/at/af compliant
• PoE++ Ports (802.3bt/at/af PoE): 8 Ports, up to 60 W per port
• PoE+ Ports (802.3at/af PoE): 16 Ports, up to 30 W per port
• Power Budget: 500 W
Dimensiones (An x Pr x Al) 17.3×13.0×1.7 in (440×330×44 mm)
Montaje Rack Mountable
Consumo máximo de energía 629.1 W (110V/60Hz)
Disipación de calor máxima 2153.45 BTU/h (110 V/60 Hz)
DESEMPEÑO
Capacidad de conmutación 200 Gbps
Tasa de reenvío de paquetes 148.80 Mpps
Tabla de direcciones MAC 32 K
Memoria de búfer de paquetes 16 Mbit
Marco Jumbo 9 KB
FUNCIONES DE SOFTWARE
Calidad de servicio • 8 priority queues
• 802.1p CoS/DSCP priority
• Queue scheduling: SP (Strict Priority), WRR (Weighted Round Robin), SP+WRR
• Bandwidth Control: Port/Flow-based Rating Limiting
• Smoother Performance
• Action for Flows: QoS remark (802.1P Remark, DSCP Remark)
Funciones L2 y L2 + • 32 IP Interfaces: Support IPv4/IPv6 Interface
• Static Routing: 48 IPv4/IPv6 Static Routes
• Static ARP: 128 static entries
• 512 ARP Entries
• Proxy ARP
• Gratuitous ARP
• DHCP Server
• DHCP Relay: DHCP Interface Relay, DHCP VLAN Relay
• DHCP L2 Relay
• Link Aggregation
• Spanning Tree Protocol
• Loopback Detection
• 802.3x Flow Control
• Mirroring
Multidifusión L2 • Supports 511 (IPv4, IPv6) IGMP groups
• IGMP Snooping
• IGMP Authentication
• Multicast VLAN Registration (MVR)
• MLD Snooping
• Multicast Filtering: 256 profiles and 16 entries per profile
Características avanzadas • Automatic Device Discovery
• Batch Configuration
• Batch Firmware Upgrading
• Intelligent Network Monitoring
• Abnormal Event Warnings
• Unified Configuration
• Reboot Schedule

ISP Features***:
• L2PT (Layer 2 Protocol Tunneling)
• Device Link Detect Protocol (DLDP)
• PPPoE ID Insertion
• ERPS
• 802.3ah Ethernet Link OAM
• DDM
VLAN • VLAN Group: Max 4K VLAN Groups
• 802.1q Tagged VLAN
• MAC VLAN: 256 Entries
• Protocol VLAN: Protocol Template 16, Protocol VLAN 16
• Private VLAN
• GVRP
• VLAN VPN: VLAN Mapping, VLAN Replace
• Voice VLAN
Lista de control de acceso • Time-based ACL
• MAC ACL: Source MAC, Destination MAC, VLAN ID, User Priority, Ether Type
• IP ACL: Source IP, Destination IP, Fragment, IP Protocol, TCP Flag, TCP/UDP Port, DSCP/IP TOS
• Combined ACL
• Packet Content ACL
• IPv6 ACL
• Policy: Mirroring, Redirect, Rate Limit, QoS Remark
• ACL applies to Port/VLAN
Seguridad • IP-MAC-Port Binding
- 512 Entries
- DHCP Snooping
- ARP Inspection
- IPv4 Source Guard: 100 Entries
• IPv6-MAC-Port Binding
- 512 Entries
- DHCPv6 Snooping
- ND Detection
- ND Snooping
- IPv6 Source Guard: 100 Entries
• DoS Defend
• DHCP Filter
• Static/Dynamic Port Security: Up to 64 MAC addresses per port
• Broadcast/Multicast/Unicast Storm Control: kbps/ratio/pps control mode
• 802.1X
- Port-based authentication
- Mac-base authentication
- VLAN Assignment
- MAB
- Guest VLAN
- Radius authentication and accountability support
• AAA (including TACACS+)
• Port Isolation
• Secure web management through HTTPS with SSLv3/TLS 1.2
• Secure Command Line Interface (CLI) management with SSHv1/SSHv2
• IP/Port/MAC-based access control
IPv6 • IPv6 Dual IPv4/IPv6
• Multicast Listener Discovery (MLD) Snooping
• IPv6 ACL
• IPv6 Interface
• Static IPv6 Routing
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP) version 6
• TCPv6/UDPv6
• IPv6 applications: DHCPv6 Client, Ping6, Tracert6, Telnet (v6), IPv6 SNMP, IPv6 SSH, IPv6 SSL, Http/Https, IPv6 TFTP
MIBs • MIB II (RFC1213)
• Interface MIB (RFC2233)
• Ethernet Interface MIB (RFC1643)
• Bridge MIB (RFC1493)
• P/Q-Bridge MIB (RFC2674)
• RMON MIB (RFC2819)
• RMON2 MIB (RFC2021)
• Radius Accounting Client MIB (RFC2620)
• Radius Authentication Client MIB (RFC2618)
• Remote Ping, Traceroute MIB (RFC2925)
• Support TP-Link private MIB
ADMINISTRACIÓN
Aplicación Omada Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.
Gestión centralizada • Omada Cloud-Based Controller
• Omada Hardware Controller
• Omada Software Controller
Acceso a la nube Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.
Aprovisionamiento sin intervención Yes. Requiring the use of Omada Cloud-Based Controller.
Funciones de gestión • Web-based GUI
• Command Line Interface (CLI) through the console port, telnet
• SNMP v1/v2c/v3: Trap/Inform, RMON (1,2,3,9 groups)
• SDM Template
• DHCP/BOOTP Client
• 802.1ab LLDP/LLDP-MED
• DHCP AutoInstall
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• EEE
• Password Recovery
• SNTP
• System Log
OTROS
Certificación CE, FCC, RoHS
contenidos del paquete • SG3428XPP-M2 Switch
• Power Cord
• Quick Installation Guide
• Rackmount Kit
• Rubber Feet
Requisitos del sistema Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
Ambiente • Operating Temperature: 0–40 ℃ (32–104 ℉);
• Storage Temperature: -40–70 ℃ (-40–158 ℉)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing

These functions require the use of the Omada SDN Controller. Zero-Touch Provisioning requires the use of the Omada Cloud-Based Controller. Go to the Omada Cloud-Based Controller Product List to find all the models supported by the Omada Cloud-Based Controller.

*PoE budget calculations are based on laboratory testing. The actual PoE power budget is not guaranteed and will vary due to client limitations and environmental factors. The maximum power output of every single PoE++ port is 60 W.

**SG3428XPP-M2 is incompatible with Passive PoE and other non-standard PoE devices. The standards refer to IEEE 802.3af/at/bt.

***ISP features can only be configured in standalone mode. 

Attention: It is recommended to use only one SM5310-T (TL-SM5310-T) module for the SG3428XPP-M2.

Desde United States?